Repressurise a Boiler with an External Filling Loop
Your system may have an external filling loop like this
If you have a system with an external filling loop, you will see two valves, one from the mains cold water, and a second that is connected to the heating system. You will also have a silver braided hose to connect the two valves to allow you to repressurise the boiler.
Take the hose and attach it to each side of the valve.
Once the hose is securely attached, fully open the valve for the mains cold water, followed by the valve that connects to the heating system. Leave the valves open until the boiler pressure is indicated at just over 1 bar. Then you can close both valves. Don’t worry if you have gone too far as this can be corrected later.
The ideal pressure is 1 bar. Don’t worry if the pressure goes too high, you can reduce this by bleeding your radiators
Leave the hose attached while you go around and bleed any air from all of the radiators in your home. Then go back to the boiler and check the pressure again – you may need to top it up again.
Once you are satisfied the pressure is at 1 bar, make sure both valves are in the closed position and remove the connecting hose. Do this over a bucket as there may be some water in the hose.
Repressurise a Boiler with a Keyed Internal Filling Loop
If you have this kind of system, you will have been provided with a key (you may have been given this as part of the installation, or it may be located in the flap underneath the boiler).
Then you need to find where to fit the key. This could vary depending on your boiler, but on a Worcester Bosch model, the port is located to the front, right hand side.
You may have a keyed internal filling loop
Align the arrow on the shaft of key with the open padlock on the port, once the key is fully engaged, turn it to the closed padlock position. Once the key is in place, open the white tap to the left of the key port slowly and watch the pressure rise. Once the pressure is at 1 bar, close the tap.
Turn the key back to the open padlock position and gently remove the key. Some water may drip out when you remove the key and this is normal.
Repressurise a Boiler with a Keyless Internal Filling Loop
This is the quickest and easiest method for repressurising a boiler and is often found on Worcester Bosch combi-boilers
The keyless filling link can be identified by a blue lever at the bottom of the boiler. To repressurise the system, simply pull down the lever until the pressure is just over 1 bar then release.
Whichever method you use to repressurise your boiler, don’t worry if you have gone too far, you can release some of the pressure by bleeding your radiators later on.
If in doubt about how to repressurise your boiler, do contact a professional.